Centralized Management Cloud Service (Subscription)

AVTECH Room Alert
AVTECH Room Alert has Digital sensor ports for temperature/humidity sensors, Switch sensor ports for water-leak, door and smoke sensors or contact signals from other devices, and auxiliary ports for Analog, Relay and signal lights.
Highlights of AVTECH Room Alert
Suited to organizations with many Room Alert devices across branches that want central management. Available as self-installed software and as Room Alert Cloud Service (annual subscription).
A management platform is included
Buying Room Alert devices includes a Room Alert Account (web) at the Base level, free and non-expiring, with upgrade eligibility under AVTECH promotions
Room Alert Manager
Software installed on your internal network: discovers and manages devices, sends alerts, logs values, draws graphs and automates actions, managing many devices from one place (downloadable with a Professional Account or higher)
Switch sensor ports
Connects contact signals from AVTECH sensors or other devices, e.g. water leak, door, UPS, generator
Email and SMS alerts
SMS requires a USB LTE Cell Modem and a SIM card
Management software used with AVTECH Room Alert
| Name | Format | What it does |
|---|---|---|
| Room Alert Account | Cloud Service (online) by subscription | Online dashboard to view devices from anywhere, with alerts, reports and maps. The Base level is free for all Room Alert customers; higher levels are annual subscriptions. |
| Room Alert Manager | Installed on your internal network (Windows) | Manage multiple Room Alert devices on the network: auto-discovery, alerts, log storage, graphs and automation. Available with a Professional Account or higher. |
| Device Discovery / Room Alert Link | Download from your Account | Tool for discovering devices on the network and connecting them to the platform |
| MT Monitor (by Monitoring Technology) | Installed on your organization's Windows server | Real-time dashboard, offline site map, Email/Telegram alerts, PDF reports, Event/Audit Log; supports Room Alert, VUTLAN and HWg via SNMP |
Compare models
| Ports / capabilities | Room Alert 3S | Room Alert 12S | Room Alert 12SR | Room Alert 32S |
|---|---|---|---|---|
| Switch sensor port ★ | 1 | 4 | 4 | 16 |
| Digital sensor port (RJ-11) | 1 | 3 | 3 | 8 |
| Analog input 0-5V | – | 1 | 1 | 2 |
| Relay output port | – | 1 | 1 | 2 |
| Light Tower & Relay Adapter port | – | 1 | 1 | 2 |
| Alerts Email | Support | Support | Support | Support |
| Alerts LINE OA | Not supported | Not supported | Not supported | Not supported |
| Alerts Telegram | Not supported | Not supported | Not supported | Not supported |
| Alerts SMS | Add-on equipment required | Add-on equipment required | Add-on equipment required | Add-on equipment required |
★ Switch sensor port Port for dry-contact (on/off) signals from sensors or other devices such as doors, smoke, water leak and UPS
Models in the group AVTECH Room Alert
Room Alert 3S
Smallest model, for small rooms or a single point View specs →
Room Alert 12S
Mid-range wall-mount model for medium-sized rooms View specs →
Room Alert 12SR
Same specs as the 12S but in a 1U rack-mount form View specs →
Room Alert 32S
Largest model with 16 Switch sensors and 8 Digital sensors for rooms with many monitoring points View specs →Compatible sensors and probes
| Equipment | Uses ports | Details |
|---|---|---|
![]() Digital Temperature Sensor |
Digital sensor port (RJ-11) ×1 | Digital temperature sensor |
![]() Digital Temperature & Humidity Sensor |
Digital sensor port (RJ-11) ×1 | Temperature and humidity sensor |
Digital Temperature & Air Flow Sensor |
Digital sensor port (RJ-11) ×1 | Temperature and airflow sensor |
![]() Digital Temperature & Analog Sensor |
Digital sensor port (RJ-11) ×1 | Adds 1 more 0-5V Analog port by using 1 Digital port |
![]() Digital Active Power Sensor RMA-DAP-SEN |
Digital sensor port (RJ-11) ×1 | Digital power-supply status detection |
![]() Flood Sensor (cable type) |
Switch sensor port ×1 | Water leak detection along a cable, connects to a Switch sensor port |
![]() Flood Sensor Spot (spot type) |
Switch sensor port ×1 | Spot water leak detection, connects to a Switch sensor port |
![]() Room Entry Sensor RMA-RE1-SEN |
Switch sensor port ×1 | Door open/close detection |
![]() Motion Sensor RMA-MOT2-SEN |
Switch sensor port ×1 | Motion detection |
![]() Power Sensor (100-240V) RMA-PS1-SEN |
Switch sensor port ×1 | Detects whether AC power is present |
![]() Mini UPS & Power Sensor RMA-MUPS-SEN |
Switch sensor port ×1 | Detects power failure, with built-in backup battery for about 15-20 minutes |
Contact signals from other devices (Switch sensor) Dry contact |
Switch sensor port ×1 | Connects an on/off contact from any device, e.g. UPS, generator, pump |
![]() Light Tower with sound, and Adapter STRYG-LT/A |
Light Tower & Relay Adapter port ×1 | Signal light and sound alarm on site, connected through the Light Tower & Relay Adapter |
![]() Relay Switch Sensor with Adapter RMA-RELAY-SEN/A |
Light Tower & Relay Adapter port ×1 | Controls up to 4 low-voltage devices through a Light Tower & Relay Adapter |
Connects equipment to the unit's Relay output |
Relay output port ×1 | For loads up to 0.3A@125VAC / 1A@24VDC |
External 0-5V analog sensor 0-5V |
Analog input 0-5V ×1 | Analog sensors with 0-5V voltage output (some models support 1-5V) |
![]() Smoke Sensor |
Switch sensor port ×1 | Smoke sensor, connects to a Switch sensor port |
LINE