Standalone HWg Cloud (free) / SensDesk

HW-Group
HW group makes network monitoring devices: Poseidon2 for 1-Wire sensors and Dry Contact, and Damocles2 for projects with many Dry Contact inputs. Supports SNMP and Modbus TCP; alerts via Email and SNMP Trap; SMS via the HWg-SMS-GW3.
Highlights of HW-Group
Suited to projects that need LAN monitoring devices usable right away with no software installation. HWg Cloud (free) can be added.
New Perseus family
HW group's new platform, available in LAN and LAN+built-in LTE versions. Supports 1-Wire UNI, Dry Contact, RS-485 Modbus RTU and WLD cable.
Poseidon2 / Damocles2
Model still on sale and widely used, for 1-Wire sensors and projects with many Dry Contact inputs
Open API
SNMP, Modbus/TCP, XML, MQTT (depending on model) for integration with other systems
Management software used with HW-Group
| Name | Format | What it does |
|---|---|---|
| MT Monitor (by Monitoring Technology) | Installed on your organization's Windows server | Real-time dashboard, offline site map, Email/Telegram alerts, PDF reports, Event/Audit Log; supports HWg via SNMP |
Compare models
| Ports / capabilities | Perseus Monitoring 140 | Perseus Monitoring 145 | Perseus Monitoring 150 | Perseus Monitoring 155 | Damocles2 MINI | Poseidon2 3268 | Damocles2 1208 | Poseidon2 3468 | Damocles2 2404 | Poseidon2 4002 |
|---|---|---|---|---|---|---|---|---|---|---|
| Dry Contact input ★ | 4 | 4 | 16 | 16 | 4 | 4 | 12 | 4 | 24 | 12 |
| 1-Wire sensors (maximum in total) | 8 | 8 | 16 | 16 | – | 8 | – | 8 | – | 16 |
| Relay output (NC/NO) | 2 | 2 | 4 | 4 | 2 | 2 | – | 2 | 4 | 4 |
| RS-485 sensor | 32 | 32 | 32 | 32 | – | – | – | – | – | 26 |
| WLD zone (water leak sensing cable) | 1 | 1 | 1 | 1 | – | – | – | – | – | – |
| Digital output (Open collector) | – | – | – | – | – | – | 8 | – | – | – |
| Alerts Email | Support | Support | Support | Support | Support | Support | Support | Support | Support | Support |
| Alerts LINE OA | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
| Alerts Telegram | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported | Not supported |
| Alerts SMS | Add-on equipment required | Support | Add-on equipment required | Support | Add-on equipment required | Add-on equipment required | Add-on equipment required | Add-on equipment required | Add-on equipment required | Add-on equipment required |
★ Dry Contact input Port for dry-contact (on/off) signals from sensors or other devices such as doors, smoke, water leak and UPS
Models in the group HW-Group
Perseus Monitoring 140
Mid-size LAN model for environmental monitoring View specs →
Perseus Monitoring 145
Mid-size model with LAN + built-in LTE for environmental monitoring View specs →
Perseus Monitoring 150
New platform: LAN (PoE), 16 Dry Contact inputs, 8 1-Wire UNI ports, RS-485 and WLD View specs →
Perseus Monitoring 155
Same as the 150 with a built-in LTE modem (SMS/calls and connection backup) View specs →
Damocles2 MINI
Compact I/O unit with 4 Dry Contact inputs and 2 Relays View specs →
Poseidon2 3268
Same as the 3266 with 2 Relay outputs View specs →
Damocles2 1208
12 Dry Contact inputs and 8 Open-collector outputs View specs →
Poseidon2 3468
Same as the 3266 with 2 high-power relays View specs →
Damocles2 2404
24 Dry Contact inputs for projects with many signals; supports PoE and -48V View specs →
Poseidon2 4002
Largest Poseidon2 model; supports 16 1-Wire sensors and RS-485 View specs →Compatible sensors and probes
| Equipment | Uses ports | Details |
|---|---|---|
1-Wire temperature sensor Temp-1Wire |
1-Wire sensors (maximum in total) ×1 | 1-Wire temperature sensor in multiple cable lengths |
1-Wire humidity sensor Humid-1Wire |
1-Wire sensors (maximum in total) ×1 | 1-Wire humidity sensor |
1-Wire temperature + humidity sensor HTemp-1Wire |
1-Wire sensors (maximum in total) ×1 | Temperature and humidity in a single sensor |
Door contact Door contact |
Dry Contact input ×1 | Door open/close detection via Dry Contact |
Smoke detector Smoke Detector FDR26 |
Dry Contact input ×1 | Connects via Dry Contact |
Dry Contact signals from other devices Dry Contact |
Dry Contact input ×1 | UPS, control cabinets, flood sensors or any other device with a dry contact |
Control devices via Relay Relay output |
Relay output (NC/NO) ×1 | Control external equipment through a relay |
Control via Open collector output Digital output |
Digital output (Open collector) ×1 | Control small loads through an Open collector output |
Industrial RS-485 sensor RS-485 |
RS-485 sensor ×1 | RS-485 (Modbus/RTU) sensor/meter, e.g. Temp/Humid RS-485 (Poseidon2 4002 and all Perseus models) |
WLD water leak sensing cable WLD cable |
WLD zone (water leak sensing cable) ×1 | Water leak cable connecting to the WLD zone of a Perseus |
LINE